CT motion SPICY
![](http://www.ulrichmedical.de/wp-content/uploads/2023/12/CTm_SPICY_zv_R1-2.png)
![](http://www.ulrichmedical.de/wp-content/uploads/2023/02/1-Slider_CT-motion-SPICY_R1-0_chili2.png)
CT motion™ SPICY
![chili chili](https://www.ulrichmedical.de/wp-content/uploads/2023/02/chili-50x26.png)
SPICY Features
![pressure-performance_150px pressure-performance_150px](https://www.ulrichmedical.de/wp-content/uploads/2023/03/pressure-performance_150px-65x120.png)
Enhanced pressure and flow performance
For examinations with high flow rates and high contrast media viscosities.
![remaining-volume_150px remaining-volume_150px](https://www.ulrichmedical.de/wp-content/uploads/2023/03/remaining-volume_150px-84x120.png)
Remaining volume indication
Easy-to-understand traffic light indication and clear display of available media volumes plus accurate ml indication.
![1L-ge_150px 1L-ge_150px](https://www.ulrichmedical.de/wp-content/uploads/2023/03/1L-ge_150px-75x120.png)
1L GE contrast media Pluspak compatibility plus heat maintaining
- Ideal media supply for high patient throughput. 4L in total (2x 1L contrast media + 2L NaCl)
- Optimal contrast media viscosity and patient comfort thanks to integrated heat maintaining
![extended-performance-date_150px extended-performance-date_150px](https://www.ulrichmedical.de/wp-content/uploads/2023/03/extended-performance-date_150px-105x120.png)
Automatic media label recognition
- Automatic media label recognition via barcode reader
- Automatic data transfer to vendor-independent PACS and DMS
- Less manual data entry necessary
![cd-adapt_150px cd-adapt_150px](https://www.ulrichmedical.de/wp-content/uploads/2023/03/cd-adapt_150px-79x120.png)
CDadaptTM
Automatic contrast density reduction (e.g. for cardiac examinations) and simultaneously reduced costs for contrast media due to lower contrast media consumption.
Multi contrast media use
![Icon_Extended_CM-Select_Tandem Icon_Extended_CM-Select_Tandem](https://www.ulrichmedical.de/wp-content/uploads/2021/05/Icon_Extended_CM-Select_Tandem-150x150.png)
Tandem for changing over contrast media
- With the same active ingredients at the touch of a button
- No changeover of the 24 h pump tubing required thanks to the automatic rinsing program
![Icon_CMLoop_Seamless Icon_CMLoop_Seamless](https://www.ulrichmedical.de/wp-content/uploads/2021/05/Icon_CMLoop_Seamless-150x150.png)
Extended tandem**
- Use of contrast media with different active ingredients
- No changeover of the 24 h pump tubing required thanks to the rinsing program
**Extended Tandem requires additional application training.
![Icon_Seamless Icon_Seamless](https://www.ulrichmedical.de/wp-content/uploads/2021/05/Icon_Seamless-150x150.png)
Seamless
- Double contrast media supply thanks to automatic switchover with identical contrast media
- Low contrast media wastage and increased patient throughput.
- Patient changeover in just a few seconds*
*Compared to our products with only one contrast media connection point
SYNCopenTM
- Interface between CT motion and CT scanner
- Simplified and safe start of the examination via Single Button Start
- Automatic transfer of the injection protocol once scan protocol has been selected
- Patient safety: clear assignment of integrated scan and injection protocols
- Quality assurance through the automatic sending of injection parameters to RIS/PACS or dose management systems
RIS/PACS Interface
- Comprehensive documentation of the contrast media injection
- Quick and standardized documentation using DICOM standard
- Reduced error sources during data collection thanks to the standardized data transfer
- Automatic documentation of the contrast media injection in PACS and/or dose management systems in combination with the patient data from the RIS
- Availability of an injection history for the last 500 injections (on the touch terminal)
Two-piece tubing system
- Optimized pump tubing XD 8151 for 24 h use for any number of injections
- Fewer insertion steps simplify set-up procedure
- Further improvement of the particle filter performance increases patient safety
- Patient tubing with two check valves
![tubing system tubing system](https://www.ulrichmedical.de/wp-content/uploads/2023/03/tubing-system-380x180.png)
Injector display
Simple, safe and fast operation
Touch terminal
- High-resolution color display
- Wireless connection to injector
- Capacitive touchscreen
Cordless operation
- 24 h battery output
- Lithium-ion battery
The CT motion is available as a wireless pedestal version for flexible positioning or as a ceiling version for small examination rooms.
![](https://www.ulrichmedical.de/wp-content/uploads/2023/12/CT-motion_SPICY_R1-3_res.png)
![Simple to use Simple to use](https://www.ulrichmedical.de/wp-content/uploads/2023/03/Simple-to-use-120x120.png)
Simple to use
- Set-up just once daily
- Rapid patient changeover
- Intuitive user interface
- Optimal contrast media management with two connection points
![Hygiene and patient safety Hygiene and patient safety](https://www.ulrichmedical.de/wp-content/uploads/2023/03/Hygiene-and-patient-safety-120x120.png)
Hygiene & patient safety
- 24 h use of the pump tubing1
- Direct injection from the original media containers
- Closed system
- Reliable protection against retrograde contamination2
- Injector and patient-side air detectors protect against air injection
![Cost-effective and efficient Cost-effective and efficient](https://www.ulrichmedical.de/wp-content/uploads/2023/03/Cost-effective-and-efficient-120x120.png)
Cost-effective and efficient
- Low costs for disposables due to 24 h approval of the pump tubing
- Optimal contrast media management using large containers
- High patient throughput thanks to efficient workflows
1 Source: GLP-compliant study: “Microbiological Contamination Control Study of CT motion System”, Report 12046497, dated: February 28, 2018, author: UL International GmbH (Grenzenstr. 13, 88416 Ochsenhausen, Germany); study is unpublished, but available on request with nondisclosure agreement.
2 Source: GLP-compliant study: “Virological evaluation of Retrograde Contamination Potential at the Pump Tubing Set (XD 8003) and the Patient Tubing Set (XD 2035) of the CT motion (XD 8000)”, Report 10874251 2.1, dated: November 12, 2015, author: UL International GmbH (Grenzenstr. 13, 88416 Ochsenhausen, Germany); study is unpublished, but available on request with nondisclosure agreement.